عربي

Free tool

Generator fuel consumption calculator

Estimate how much diesel your generator burns, in litres per hour and per day, and how long a full tank will last.

100 kVA ≈ 80 kW at a 0.8 power factor.
How much of its full output the generator supplies, on average.
litres

Estimate

Diesel per hour
18.3 litres
Diesel per day
183 litres
Diesel per 30 days
5,496 litres
Order diesel

How the estimate works

The calculator uses a published diesel generator fuel consumption chart from Generator Source. It gives fuel use in US gallons per hour for generators from 20 to 2,250 kW at quarter, half, three-quarter and full load. We convert gallons to litres and interpolate between the chart’s sizes and load points.

Generators are usually rated in kVA. The calculator converts kVA to kW at a power factor of 0.8, the usual basis for generator ratings.

Treat the result as an estimate. Real consumption depends on the engine model, its age and servicing, the air temperature and how steady the load is. Your generator’s data sheet gives the exact figures.

Running a diesel generator at a light load for long periods can cause wet stacking, where unburnt fuel builds up in the exhaust. A generator sized close to its load also burns less diesel for each kilowatt-hour it produces.

Diesel use by generator size

Estimated litres per hour, from the published chart (Generator Source)
Size (kW)About (kVA)25% load50% load75% loadFull load
20252.33.44.96.1
30384.96.89.111.0
40506.18.712.115.1
60756.811.014.418.2
75949.112.917.423.1
1001259.815.522.028.0
12515611.718.926.934.4
15018813.622.331.841.3
20025017.829.141.654.5
25031321.636.051.568.1
30037525.742.860.981.4
40050033.756.480.6108.3
50062541.670.099.9135.1
75093861.7103.7148.8202.1
1,0001,25081.8137.8197.2269.1
1,5001,875121.9205.5294.5403.1
2,0002,500162.0273.3391.8537.1

FAQ

Generator fuel use: common questions

How much diesel does a 100 kVA generator use per hour?

A 100 kVA generator is about 80 kW. By the published chart, it uses about 24 litres an hour at full load, 18 at three-quarter load and 13 at half load. Check the generator’s data sheet for its exact figures.

How much diesel does a 500 kVA generator use per hour?

A 500 kVA generator is about 400 kW. By the published chart, it uses about 108 litres an hour at full load, 81 at three-quarter load and 56 at half load.

How long will a generator run on a full tank?

Divide the tank capacity in litres by the litres used per hour. For example, a 500-litre tank on a generator using 20 litres an hour lasts about 25 hours. The calculator above works this out for your generator.

How do I convert kVA to kW?

Multiply by the power factor, usually 0.8 for generators. A 250 kVA generator is about 200 kW.

Why is my generator’s real fuel use different?

The chart is an average across makes and models. Engine design, age, servicing, air temperature and how steady the load is all change real consumption.

Contact

Order diesel or open an account

Fill in the form and we will reply by email or phone. You can also write to us directly.

OfficeShop, Unit 1-19-9, Sheikh Saqr Bin Muhammad Al Qasimi Street, Al Qasidat, Ras Al Khaimah, UAEOpen in Google Maps ↗
Email us

Send a request

What do you need?
An estimate is fine

We only use your details to reply to this request.